FM Transmitter Measurement Report
Created: 2019-10-14 02-58-25
Measuring equipment: P75/P175/P275
http://monitor.dxradio.cz
Station Details
Frequency Signal Reception Station Name
102.00 MHz 4/5, 36 dBuV R-DVOJKA ; Brno/Kojál 83.2kW
Pilot RDS Phase Difference
7.8 kHz 2.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
20 kHz 49 kHz 848 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-0,7 dBr 0,02 dBr 0,7 dBr 29,1
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" " 232E 0 (No PTY) 0 0 0 0 --:--
RT
-
AF EON
-
FM Scope Station: 102.00 MHz, signal: 4/5 (36 dBuV) Max at: 49 kHz MIN: 20 kHz % above 76 kHz: 0,0000 Acquired: 2019.10.14 2:57:20 Total samples: 848 Equivalent time: 0:00:42 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 10 20 30