<LOGO>
FM Transmitter Measurement Report
Created: 2020-07-03 11-41-49
Measuring equipment: P75/P175/P275
http://monitor.dxradio.cz
Station Details
Frequency Signal Reception Station Name
100.90 MHz 5/5, 46 dBuV IMPULS ; Jeseník/Praděd 20kW
Pilot RDS Phase Difference
0.0 kHz 2.5 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
4 kHz 36 kHz 19058 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-2,1 dBr -1,11 dBr -0,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" IMPULS " 2203 1 (News) 1 0 1 1 --:--
RT
"RADIO IMPULS - ZIJEME CESKOU MUZIKOU! "
AF EON
87.6, 89.0, 100.3, 100.5, 100.9, 102.3, 106.0 MHz -
FM Scope Station: 100.90 MHz, signal: 5/5 (46 dBuV) Max at: 36 kHz MIN: 4 kHz % above 76 kHz: 0,0000 Acquired: 2020.07.03 11:40:45 Total samples: 19058 Equivalent time: 0:15:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500
FM Scope MAX: -0,6 dBr MIN: -2,1 dBr AVE: -1,11 dBr % above 0,2 dBr: 0,0 Last value: -0,8 dBr (2020.07.03 11:40:43) Station: 100.90 MHz, signal: 5/5 (46 dBuV) 11:26 11:28 11:30 11:32 11:34 11:36 11:38 11:40 0 50 100 Dev. MAX [kHz] -2 0 Pm [dBr] 0 5 Signal Quality