<LOGO>
FM Transmitter Measurement Report
Created: 2023-01-12 21-42-57
Measuring equipment: P75/P175/P275
http://monitor.dxradio.cz
Station Details
Frequency Signal Reception Station Name
107.60 MHz 3/5, 36 dBuV BEAT ; Šumperk/Kolšov 0.5kW
Pilot RDS Phase Difference
4.3 kHz 2.2 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
4 kHz 6 kHz 1763 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-5,4 dBr -1,45 dBr -0,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" " 0000 0 (No PTY) 0 0 0 0 --:--
RT
-
AF EON
-
FM Scope Station: 107.60 MHz, signal: 3/5 (36 dBuV) Max at: 6 kHz MIN: 4 kHz % above 76 kHz: 0,0000 Acquired: 2023.01.12 21:41:53 Total samples: 1763 Equivalent time: 0:01:28 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100 150
FM Scope MAX: -0,2 dBr MIN: -5,4 dBr AVE: -1,45 dBr % above 0,2 dBr: 0,0 Last value: -1,6 dBr (2023.01.12 21:41:52) Station: 107.60 MHz, signal: 3/5 (36 dBuV) 21:28 21:30 21:32 21:34 21:36 21:38 21:40 0 50 100 Dev. MAX [kHz] -5 0 Pm [dBr] 0 5 Signal Quality