FM Transmitter Measurement Report
Created: 2019-10-15 09-24-43
Measuring equipment: P75/P175/P275
http://monitor.dxradio.cz
Station Details
Frequency Signal Reception Station Name
97.10 MHz 4/5, 36 dBuV * RUBI * ; Olomouc/Jedová 5kW
Pilot RDS Phase Difference
7.2 kHz 5.7 kHz -1 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
21 kHz 45 kHz 14610 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-0,8 dBr -0,46 dBr -0,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"REPUBLIC" 2B28 10 (Pop M) 1 0 1 1 --:--
RT
"GALANTIS FT ONE REPUBLIC - BONES "
AF EON
90.0, 93.1, 95.4, 95.6, 96.4, 97.1, 105.4 MHz -
FM Scope Station: 97.10 MHz, signal: 4/5 (36 dBuV) Max at: 45 kHz MIN: 21 kHz % above 76 kHz: 0,0000 Acquired: 2019.10.15 9:23:38 Total samples: 14610 Equivalent time: 0:12:10 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: -0,3 dBr MIN: -0,8 dBr AVE: -0,46 dBr % above 0,2 dBr: 0,0 Last value: -0,4 dBr (2019.10.15 9:23:37) Station: 97.10 MHz, signal: 4/5 (36 dBuV) 09:10 09:12 09:14 09:16 09:18 09:20 09:22 0 50 100 Dev. MAX [kHz] -1 0 1 Pm [dBr] 0 5 Signal Quality