FM Transmitter Measurement Report
Created: 2019-10-13 11-51-56
Measuring equipment: P75/P175/P275
http://monitor.dxradio.cz
Station Details
Frequency Signal Reception Station Name
97.10 MHz 4/5, 37 dBuV * RUBI * ; Olomouc/Jedová 5kW
Pilot RDS Phase Difference
7.1 kHz 6.0 kHz -2 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
23 kHz 42 kHz 8129 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-0,5 dBr -0,18 dBr 0,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"LP - LOS" 2B28 10 (Pop M) 1 0 1 1 --:--
RT
"LP T ON YOU H RLP - LOST ON YOU "
AF EON
90.0, 93.1, 95.4, 95.6, 96.4, 97.1, 105.4 MHz -
FM Scope Station: 97.10 MHz, signal: 4/5 (37 dBuV) Max at: 42 kHz MIN: 23 kHz % above 76 kHz: 0,0000 Acquired: 2019.10.13 11:50:51 Total samples: 8129 Equivalent time: 0:06:46 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400