Online monitoring VKV
FM Transmitter Measurement Report
Created: 2019-08-15 08-25-11
Measuring equipment: P75/P175/P275
http://monitor.dxradio.cz
Station Details
Frequency Signal Reception Station Name
97.10 MHz 4/5, 38 dBuV * RUBI * ; Olomouc/Jedová 5kW
Pilot RDS Phase Difference
6.8 kHz 6.2 kHz -21 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
20 kHz 47 kHz 15032 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-0,5 dBr -0,19 dBr 0,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"E SMOD -" 2B28 10 (Pop M) 1 0 1 1 --:--
RT
"DESM NDES - IN MY LO DESM ME CHY - IN MY OD "
AF EON
90.0, 93.1, 95.4, 95.6, 96.4, 97.1, 105.4 MHz -
FM Scope Station: 97.10 MHz, signal: 4/5 (38 dBuV) Max at: 47 kHz MIN: 20 kHz % above 76 kHz: 0,0000 Acquired: 2019.08.15 8:24:07 Total samples: 15032 Equivalent time: 0:12:31 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500
FM Scope MAX: 0,0 dBr MIN: -0,5 dBr AVE: -0,19 dBr % above 0,2 dBr: 0,0 Last value: -0,3 dBr (2019.08.15 8:24:05) Station: 97.10 MHz, signal: 4/5 (38 dBuV) 08:10 08:12 08:14 08:16 08:18 08:20 08:22 08:24 0 50 100 Dev. MAX [kHz] -1 0 1 Pm [dBr] 0 5 Signal Quality