<LOGO>
FM Transmitter Measurement Report
Created: 2019-08-04 18-21-46
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
97.10 MHz 3/5, 37 dBuV * RUBI * ; Olomouc/Jedová 5kW
Pilot RDS Phase Difference
6.9 kHz 6.9 kHz -20 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
23 kHz 51 kHz 10355 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-0,3 dBr 0,06 dBr 0,3 dBr 4,9
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"PTAKUSTI" 2B28 10 (Pop M) 1 0 1 1 --:--
RT
"PT K - E O R US "
AF EON
90.0, 93.1, 95.4, 95.6, 96.4, 97.1, 105.4 MHz -
FM Scope Station: 97.10 MHz, signal: 3/5 (37 dBuV) Max at: 51 kHz MIN: 23 kHz % above 76 kHz: 0,0000 Acquired: 2019.08.04 18:20:42 Total samples: 10355 Equivalent time: 0:08:37 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 0,3 dBr MIN: -0,3 dBr AVE: 0,06 dBr % above 0,2 dBr: 4,9 Last value: 0,2 dBr (2019.08.04 18:20:41) Station: 97.10 MHz, signal: 4/5 (37 dBuV) 18:06 18:08 18:10 18:12 18:14 18:16 18:18 18:20 0 50 100 Dev. MAX [kHz] -1 0 1 Pm [dBr] 0 5 Signal Quality