<LOGO>
FM Transmitter Measurement Report
Created: 2019-08-02 07-06-10
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
97.10 MHz 4/5, 37 dBuV * RUBI * ; Olomouc/Jedová 5kW
Pilot RDS Phase Difference
7.0 kHz 6.8 kHz -19 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
26 kHz 48 kHz 11350 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-0,2 dBr 0,01 dBr 0,3 dBr 6,4
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"RY - MEX" 2B28 10 (Pop M) 1 0 1 1 --:--
RT
"TRI SESTRY - MEX TRI SESTRY - MEXIKO "
AF EON
90.0, 93.1, 95.4, 95.6, 96.4, 97.1, 105.4 MHz -
FM Scope Station: 97.10 MHz, signal: 4/5 (37 dBuV) Max at: 48 kHz MIN: 26 kHz % above 76 kHz: 0,0000 Acquired: 2019.08.02 7:05:06 Total samples: 11350 Equivalent time: 0:09:27 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 0,3 dBr MIN: -0,2 dBr AVE: 0,01 dBr % above 0,2 dBr: 6,4 Last value: 0,0 dBr (2019.08.02 7:05:05) Station: 97.10 MHz, signal: 4/5 (37 dBuV) 06:52 06:54 06:56 06:58 07:00 07:02 07:04 0 50 100 Dev. MAX [kHz] -1 0 1 Pm [dBr] 0 5 Signal Quality