<LOGO>
FM Transmitter Measurement Report
Created: 2019-07-17 22-07-06
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
97.10 MHz 4/5, 37 dBuV * RUBI * ; Olomouc/Jedová 5kW
Pilot RDS Phase Difference
6.9 kHz 6.5 kHz -3 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
25 kHz 47 kHz 8050 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-0,3 dBr 0,05 dBr 0,3 dBr 0,3
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"N EDDI " 2B28 10 (Pop M) 1 0 1 1 --:--
RT
"FREDDIE URY LI MY "
AF EON
90.0, 93.1, 95.4, 95.6, 96.4, 97.1, 105.4 MHz -
FM Scope Station: 97.10 MHz, signal: 4/5 (37 dBuV) Max at: 47 kHz MIN: 25 kHz % above 76 kHz: 0,0000 Acquired: 2019.07.17 22:06:02 Total samples: 8050 Equivalent time: 0:06:42 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 0,3 dBr MIN: -0,3 dBr AVE: 0,05 dBr % above 0,2 dBr: 0,3 Last value: 0,2 dBr (2019.07.17 22:06:01) Station: 97.10 MHz, signal: 4/5 (37 dBuV) 21:52 21:54 21:56 21:58 22:00 22:02 22:04 22:06 0 50 100 Dev. MAX [kHz] -1 0 1 Pm [dBr] 0 5 Signal Quality