<LOGO>
FM Transmitter Measurement Report
Created: 2019-07-09 01-04-15
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
97.10 MHz 3/5, 37 dBuV * RUBI * ; Olomouc/Jedová 5kW
Pilot RDS Phase Difference
6.8 kHz 5.5 kHz -14 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
20 kHz 44 kHz 11786 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-0,9 dBr -0,44 dBr -0,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" - MOTYL" 2B28 10 (Pop M) 1 0 1 1 --:--
RT
"MANDRAGE - MOTYLI MANDRAGE - MOTYLI "
AF EON
90.0, 93.1, 95.4, 95.6, 96.4, 97.1, 105.4 MHz -
FM Scope Station: 97.10 MHz, signal: 3/5 (37 dBuV) Max at: 44 kHz MIN: 20 kHz % above 76 kHz: 0,0000 Acquired: 2019.07.09 1:03:11 Total samples: 11786 Equivalent time: 0:09:49 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: -0,1 dBr MIN: -0,9 dBr AVE: -0,44 dBr % above 0,2 dBr: 0,0 Last value: -0,9 dBr (2019.07.09 1:03:09) Station: 97.10 MHz, signal: 3/5 (37 dBuV) 00:50 00:52 00:54 00:56 00:58 01:00 01:02 0 50 100 Dev. MAX [kHz] -1 0 1 Pm [dBr] 0 5 Signal Quality