FM Transmitter Measurement Report
Created: 2019-11-23 21-07-46
Measuring equipment: P75/P175/P275
http://monitor.dxradio.cz
Station Details
Frequency Signal Reception Station Name
92.30 MHz 3/5, 38 dBuV * HANA * ; Olomouc/Jedová 5kW
Pilot RDS Phase Difference
6.7 kHz 3.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
17 kHz 32 kHz 4508 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,1 dBr -0,72 dBr -0,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" " 0000 0 (No PTY) 0 0 0 0 --:--
RT
-
AF EON
-
FM Scope Station: 92.30 MHz, signal: 3/5 (38 dBuV) Max at: 32 kHz MIN: 17 kHz % above 76 kHz: 0,0000 Acquired: 2019.11.23 21:06:40 Total samples: 4508 Equivalent time: 0:03:45 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200
FM Scope MAX: -0,3 dBr MIN: -1,1 dBr AVE: -0,72 dBr % above 0,2 dBr: 0,0 Last value: -0,5 dBr (2019.11.23 21:06:39) Station: 92.30 MHz, signal: 3/5 (38 dBuV) 20:52 20:54 20:56 20:58 21:00 21:02 21:04 21:06 0 50 100 Dev. MAX [kHz] -2 -1 0 1 Pm [dBr] 0 5 Signal Quality