FM Transmitter Measurement Report
Created: 2019-11-23 17-42-09
Measuring equipment: P75/P175/P275
http://monitor.dxradio.cz
Station Details
Frequency Signal Reception Station Name
92.30 MHz 3/5, 37 dBuV * HANA * ; Olomouc/Jedová 5kW
Pilot RDS Phase Difference
6.6 kHz 3.5 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
16 kHz 33 kHz 4844 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,0 dBr -0,62 dBr -0,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" " 0000 0 (No PTY) 0 0 0 0 --:--
RT
-
AF EON
-
FM Scope Station: 92.30 MHz, signal: 3/5 (37 dBuV) Max at: 33 kHz MIN: 16 kHz % above 76 kHz: 0,0000 Acquired: 2019.11.23 17:41:04 Total samples: 4844 Equivalent time: 0:04:02 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200