FM Transmitter Measurement Report
Created: 2019-10-16 17-14-04
Measuring equipment: P75/P175/P275
http://monitor.dxradio.cz
Station Details
Frequency Signal Reception Station Name
92.30 MHz 5/5, 38 dBuV * HANA * ; Olomouc/Jedová 5kW
Pilot RDS Phase Difference
6.7 kHz 0.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 41 kHz 18786 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,4 dBr -0,79 dBr 0,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" " 2B16 0 (No PTY) 0 0 0 0 --:--
RT
-
AF EON
-
FM Scope Station: 92.30 MHz, signal: 5/5 (38 dBuV) Max at: 41 kHz MIN: 11 kHz % above 76 kHz: 0,0000 Acquired: 2019.10.16 17:13:00 Total samples: 18786 Equivalent time: 0:15:39 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 0,0 dBr MIN: -1,4 dBr AVE: -0,79 dBr % above 0,2 dBr: 0,0 Last value: -1,0 dBr (2019.10.16 17:12:59) Station: 92.30 MHz, signal: 5/5 (37 dBuV) 17:00 17:02 17:04 17:06 17:08 17:10 17:12 0 50 100 Dev. MAX [kHz] -2 -1 0 1 Pm [dBr] 0 5 Signal Quality