FM Transmitter Measurement Report
Created: 2019-10-12 14-57-13
Measuring equipment: P75/P175/P275
http://monitor.dxradio.cz
Station Details
Frequency Signal Reception Station Name
92.30 MHz 5/5, 37 dBuV * HANA * ; Olomouc/Jedová 5kW
Pilot RDS Phase Difference
6.8 kHz 0.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 37 kHz 19058 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,5 dBr -0,72 dBr -0,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"* HANA *" 2B16 10 (Pop M) 1 0 1 1 --:--
RT
"VY "
AF EON
88.4, 90.1, 91.9, 92.3, 96.2, 97.8, 98.6, 105.1 MHz -
FM Scope Station: 92.30 MHz, signal: 5/5 (37 dBuV) Max at: 37 kHz MIN: 10 kHz % above 76 kHz: 0,0000 Acquired: 2019.10.12 14:56:08 Total samples: 19058 Equivalent time: 0:15:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000