<LOGO>
FM Transmitter Measurement Report
Created: 2019-08-01 14-06-46
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
92.30 MHz 3/5, 39 dBuV * HANA * ; Olomouc/Jedová 5kW
Pilot RDS Phase Difference
6.7 kHz 2.1 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
16 kHz 37 kHz 6499 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,2 dBr -0,81 dBr -0,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" " 0000 0 (No PTY) 0 0 0 0 --:--
RT
-
AF EON
-
FM Scope Station: 92.30 MHz, signal: 3/5 (39 dBuV) Max at: 37 kHz MIN: 16 kHz % above 76 kHz: 0,0000 Acquired: 2019.08.01 14:05:42 Total samples: 6499 Equivalent time: 0:05:24 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: -0,4 dBr MIN: -1,2 dBr AVE: -0,81 dBr % above 0,2 dBr: 0,0 Last value: -0,6 dBr (2019.08.01 14:05:41) Station: 92.30 MHz, signal: 3/5 (39 dBuV) 13:52 13:54 13:56 13:58 14:00 14:02 14:04 0 50 100 Dev. MAX [kHz] -2 -1 0 1 Pm [dBr] 0 5 Signal Quality