<LOGO>
FM Transmitter Measurement Report
Created: 2019-07-12 17-37-13
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
92.30 MHz 4/5, 40 dBuV * HANA * ; Olomouc/Jedová 5kW
Pilot RDS Phase Difference
7.0 kHz 2.8 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
16 kHz 39 kHz 14700 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,1 dBr -0,54 dBr -0,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" " 0000 0 (No PTY) 0 0 0 0 --:--
RT
-
AF EON
-
FM Scope Station: 92.30 MHz, signal: 4/5 (40 dBuV) Max at: 39 kHz MIN: 16 kHz % above 76 kHz: 0,0000 Acquired: 2019.07.12 17:36:09 Total samples: 14700 Equivalent time: 0:12:15 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500
FM Scope MAX: -0,3 dBr MIN: -1,1 dBr AVE: -0,54 dBr % above 0,2 dBr: 0,0 Last value: -0,8 dBr (2019.07.12 17:36:07) Station: 92.30 MHz, signal: 4/5 (40 dBuV) 17:22 17:24 17:26 17:28 17:30 17:32 17:34 17:36 0 50 100 Dev. MAX [kHz] -2 -1 0 1 Pm [dBr] 0 5 Signal Quality