<LOGO>
FM Transmitter Measurement Report
Created: 2019-07-12 09-48-04
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
92.30 MHz 4/5, 39 dBuV * HANA * ; Olomouc/Jedová 5kW
Pilot RDS Phase Difference
7.1 kHz 3.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
17 kHz 36 kHz 13194 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,4 dBr -0,80 dBr -0,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" " 0000 0 (No PTY) 0 0 0 0 --:--
RT
-
AF EON
-
FM Scope Station: 92.30 MHz, signal: 4/5 (39 dBuV) Max at: 36 kHz MIN: 17 kHz % above 76 kHz: 0,0000 Acquired: 2019.07.12 9:47:00 Total samples: 13194 Equivalent time: 0:10:59 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: -0,4 dBr MIN: -1,4 dBr AVE: -0,80 dBr % above 0,2 dBr: 0,0 Last value: -0,8 dBr (2019.07.12 9:46:59) Station: 92.30 MHz, signal: 4/5 (39 dBuV) 09:34 09:36 09:38 09:40 09:42 09:44 09:46 0 50 100 Dev. MAX [kHz] -2 -1 0 1 Pm [dBr] 0 5 Signal Quality