<LOGO>
FM Transmitter Measurement Report
Created: 2019-07-12 12-11-04
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
106.80 MHz 5/5, 38 dBuV R-OL ; Jeseník/Praděd 20kW
Pilot RDS Phase Difference
7.8 kHz 2.5 kHz 4 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 44 kHz 12547 8,8467
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-2,1 dBr -0,46 dBr 0,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-OL " 2B07 9 (Varied) 1 0 1 1 12:10, 12.07.2019
RT
" R-OL R-OL R-OL R-OL "
AF EON
88.7, 92.8, 101.6, 106.8 MHz -
FM Scope Station: 106.80 MHz, signal: 5/5 (38 dBuV) Max at: 44 kHz MIN: 11 kHz % above 76 kHz: 8,8467 Acquired: 2019.07.12 12:10:00 Total samples: 12547 Equivalent time: 0:10:27 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300
FM Scope MAX: 0,1 dBr MIN: -2,1 dBr AVE: -0,46 dBr % above 0,2 dBr: 0,0 Last value: -1,9 dBr (2019.07.12 12:09:59) Station: 106.80 MHz, signal: 5/5 (39 dBuV) 11:56 11:58 12:00 12:02 12:04 12:06 12:08 0 50 100 Dev. MAX [kHz] -2 0 Pm [dBr] 0 5 Signal Quality