<LOGO>
FM Transmitter Measurement Report
Created: 2023-01-22 14-35-21
Measuring equipment: P75/P175/P275
http://monitor.dxradio.cz
Station Details
Frequency Signal Reception Station Name
101.50 MHz 5/5, 67 dBuV R-PLUS ; Šumperk/Vrchlického 0.2kW
Pilot RDS Phase Difference
0.0 kHz 2.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
1 kHz 42 kHz 19117 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-2,8 dBr -1,26 dBr -0,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 1 (News) 1 0 0 0 14:35, 22.01.2023
RT
"Dokument - V 82 letech zemrel novinar a byvaly reditel radia ..."
AF EON
90.7, 93.1, 97.5, 101.5, 102.5, 105.8, 107.2 MHz -
FM Scope Station: 101.50 MHz, signal: 5/5 (67 dBuV) Max at: 42 kHz MIN: 1 kHz % above 76 kHz: 0,0000 Acquired: 2023.01.22 14:34:18 Total samples: 19117 Equivalent time: 0:15:55 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: -0,5 dBr MIN: -2,8 dBr AVE: -1,26 dBr % above 0,2 dBr: 0,0 Last value: -1,4 dBr (2023.01.22 14:34:17) Station: 101.50 MHz, signal: 5/5 (67 dBuV) 14:20 14:22 14:24 14:26 14:28 14:30 14:32 14:34 0 50 100 Dev. MAX [kHz] -2 0 Pm [dBr] 0 5 Signal Quality