<LOGO>
FM Transmitter Measurement Report
Created: 2020-05-25 00-41-52
Measuring equipment: P75/P175/P275
http://monitor.dxradio.cz
Station Details
Frequency Signal Reception Station Name
101.50 MHz 5/5, 72 dBuV R-PLUS ; ҆umperk/Vrchlick√©ho 0.2kW
Pilot RDS Phase Difference
0.0 kHz 2.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
1 kHz 4 kHz 19118 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-3,7 dBr -2,05 dBr -1,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 0 (No PTY) 1 0 1 0 0:41, 25.05.2020
RT
" R-PLUS R-PLUS R-PLUS R-PLUS "
AF EON
90.7, 93.1, 97.5, 101.5, 102.5, 105.8, 107.2 MHz -
FM Scope Station: 101.50 MHz, signal: 5/5 (72 dBuV) Max at: 4 kHz MIN: 1 kHz % above 76 kHz: 0,0000 Acquired: 2020.05.25 0:40:48 Total samples: 19118 Equivalent time: 0:15:55 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: -1,0 dBr MIN: -3,7 dBr AVE: -2,05 dBr % above 0,2 dBr: 0,0 Last value: -1,9 dBr (2020.05.25 0:40:47) Station: 101.50 MHz, signal: 5/5 (72 dBuV) 00:26 00:28 00:30 00:32 00:34 00:36 00:38 00:40 0 50 100 Dev. MAX [kHz] -4 -2 0 Pm [dBr] 0 5 Signal Quality