<LOGO>
FM Transmitter Measurement Report
Created: 2020-05-12 05-32-10
Measuring equipment: P75/P175/P275
http://monitor.dxradio.cz
Station Details
Frequency Signal Reception Station Name
101.50 MHz 5/5, 76 dBuV R-PLUS ; ҆umperk/Vrchlick√©ho 0.2kW
Pilot RDS Phase Difference
0.0 kHz 2.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
2 kHz 4 kHz 19100 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,7 dBr -1,34 dBr -0,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 0 (No PTY) 1 0 1 0 5:32, 12.05.2020
RT
" R-PLUS R-PLUS R-PLUS R-PLUS "
AF EON
90.7, 93.1, 97.5, 101.5, 102.5, 105.8, 107.2 MHz -
FM Scope Station: 101.50 MHz, signal: 5/5 (76 dBuV) Max at: 4 kHz MIN: 2 kHz % above 76 kHz: 0,0000 Acquired: 2020.05.12 5:31:06 Total samples: 19100 Equivalent time: 0:15:55 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: -0,9 dBr MIN: -1,7 dBr AVE: -1,34 dBr % above 0,2 dBr: 0,0 Last value: -1,1 dBr (2020.05.12 5:31:05) Station: 101.50 MHz, signal: 5/5 (76 dBuV) 05:18 05:20 05:22 05:24 05:26 05:28 05:30 0 50 100 Dev. MAX [kHz] -2 -1 0 1 Pm [dBr] 0 5 Signal Quality