<LOGO>
FM Transmitter Measurement Report
Created: 2020-04-13 16-42-22
Measuring equipment: P75/P175/P275
http://monitor.dxradio.cz
Station Details
Frequency Signal Reception Station Name
101.50 MHz 4/5, 42 dBuV R-PLUS ; ҆umperk/Vrchlick√©ho 0.2kW
Pilot RDS Phase Difference
0.0 kHz 2.3 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
6 kHz 9 kHz 12888 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-3,9 dBr -1,70 dBr -0,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 0 (No PTY) 0 0 1 0 --:--
RT
"Intervie Plus "
AF EON
90.7, 93.1, 97.5, 101.5, 102.5, 105.8, 107.2 MHz -
FM Scope Station: 101.50 MHz, signal: 4/5 (42 dBuV) Max at: 9 kHz MIN: 6 kHz % above 76 kHz: 0,0000 Acquired: 2020.04.13 16:41:17 Total samples: 12888 Equivalent time: 0:10:44 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: -0,3 dBr MIN: -3,9 dBr AVE: -1,70 dBr % above 0,2 dBr: 0,0 Last value: -2,0 dBr (2020.04.13 16:41:16) Station: 101.50 MHz, signal: 4/5 (42 dBuV) 16:28 16:30 16:32 16:34 16:36 16:38 16:40 0 50 100 Dev. MAX [kHz] -4 -2 0 Pm [dBr] 0 5 Signal Quality