FM Transmitter Measurement Report
Created: 2019-08-16 10-03-01
Measuring equipment: P75/P175/P275
http://monitor.dxradio.cz
Station Details
Frequency Signal Reception Station Name
100.90 MHz 5/5, 47 dBuV IMPULS ; Jeseník/Praděd 20kW
Pilot RDS Phase Difference
0.0 kHz 2.8 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
2 kHz 36 kHz 19120 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-2,4 dBr -1,22 dBr -0,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" IMPULS " 2203 1 (News) 1 0 1 1 --:--
RT
"RADIO IMPULS - ZIJEME CESKOU MUZIKOU! "
AF EON
87.6, 89.0, 100.3, 100.5, 100.9, 102.3, 106.0 MHz -
FM Scope Station: 100.90 MHz, signal: 5/5 (47 dBuV) Max at: 36 kHz MIN: 2 kHz % above 76 kHz: 0,0000 Acquired: 2019.08.16 10:01:57 Total samples: 19120 Equivalent time: 0:15:56 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500