<LOGO>
FM Transmitter Measurement Report
Created: 2019-07-23 00-23-21
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
100.90 MHz 5/5, 47 dBuV IMPULS ; Jeseník/Praděd 20kW
Pilot RDS Phase Difference
0.0 kHz 2.8 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
4 kHz 35 kHz 19080 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,4 dBr -1,07 dBr -0,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" IMPULS " 2203 1 (News) 1 0 1 1 --:--
RT
"RADIO IMPULS - ZIJEME CESKOU MUZIKOU! "
AF EON
87.6, 89.0, 100.3, 100.5, 100.9, 102.3, 106.0 MHz -
FM Scope Station: 100.90 MHz, signal: 5/5 (47 dBuV) Max at: 35 kHz MIN: 4 kHz % above 76 kHz: 0,0000 Acquired: 2019.07.23 0:22:17 Total samples: 19080 Equivalent time: 0:15:54 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500
FM Scope MAX: -0,7 dBr MIN: -1,4 dBr AVE: -1,07 dBr % above 0,2 dBr: 0,0 Last value: -0,9 dBr (2019.07.23 0:22:16) Station: 100.90 MHz, signal: 5/5 (47 dBuV) 00:08 00:10 00:12 00:14 00:16 00:18 00:20 00:22 0 50 100 Dev. MAX [kHz] -2 -1 0 1 Pm [dBr] 0 5 Signal Quality