<LOGO>
FM Transmitter Measurement Report
Created: 2019-07-20 06-53-21
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
100.00 MHz 5/5, 62 dBuV SKYROCK ; Ĺ umperk/Kovex 0.2kW
Pilot RDS Phase Difference
4.9 kHz 1.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
5 kHz 27 kHz 19160 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-10,5 dBr -5,04 dBr -3,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SKYROCK " 24B3 11 (Rock M) 1 0 1 0 6:56, 20.07.2019
RT
" "
AF EON
88.7, 91.8, 99.7, 100.0, 100.2, 103.1, 103.7, 104.9, 107.5 MHz -
FM Scope Station: 100.00 MHz, signal: 5/5 (62 dBuV) Max at: 27 kHz MIN: 5 kHz % above 76 kHz: 0,0000 Acquired: 2019.07.20 6:52:17 Total samples: 19160 Equivalent time: 0:15:58 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: -3,8 dBr MIN: -10,5 dBr AVE: -5,04 dBr % above 0,2 dBr: 0,0 Last value: -10,5 dBr (2019.07.20 6:52:16) Station: 100.00 MHz, signal: 5/5 (62 dBuV) 06:38 06:40 06:42 06:44 06:46 06:48 06:50 06:52 0 50 100 Dev. MAX [kHz] -10 -5 0 Pm [dBr] 0 5 Signal Quality